News Center
2021-09-26
Environmental monitoring announcement in the first quarter of 2021
I. Basic information
Business Name |
Shandong Futong Chemical Co., Ltd. |
Legal Representative |
Wang Jiayong |
|
Affiliate Company |
Organic chemical raw material manufacturing |
Production Cycle |
300 days |
|
Location |
East longitude: 118 degrees 49 minutes 04 seconds North latitude: 37 degrees 11 minutes 07 seconds |
|||
Contacts |
Zhao Qingfeng |
Contact |
13964795585 |
|
Name of commissioned testing agency |
Shandong Weike Testing Service Co., Ltd. |
II. Self-monitoring results
Organized exhaust gas |
|||||||
Sampling point |
Monitoring items |
Monitoring results |
Standard Limits |
Compliance |
Layout and direction |
||
Process exhaust gas stack sampling port |
Low concentration of particulate matter |
4.4mg/Nm³ |
10mg/Nm³ |
On target |
Processed to atmosphere |
||
Non-Methane Total Hydrocarbons |
22.9mg/Nm³ |
60mg/Nm³ |
On target |
Processed to atmosphere |
|||
Hydrogen fluoride |
2mg/Nm³ |
9mg/Nm³ |
On target |
Processed to atmosphere |
|||
Bromine |
0.3mg/Nm³ |
65mg/Nm³ |
On target |
Processed to atmosphere |
|||
Sampling port of exhaust pipe of sewage station |
Non-Methane Total Hydrocarbons |
27.9mg/Nm³ |
100mg/Nm³ |
On target |
Emitted to the atmosphere after treatment |
||
Hydrogen sulfide |
0.057mg/Nm³ |
3mg/Nm³ |
On target |
Processed to atmosphere |
|||
Hydrogen bromide |
0.77mg/Nm³ |
100mg/Nm³ |
On target |
Processed to atmosphere |
|||
Unorganized exhaust |
Non-Methane Total Hydrocarbons |
0.92mg/Nm³ |
2mg/Nm³ |
On target |
Atmospheric |
||
Ammonia |
0.11mg/Nm³ |
1.0mg/Nm³ |
On target |
Atmospheric |
|||
Fluoride |
ND |
0.02mg/Nm³ |
On target |
Atmospheric |
|||
Hydrogen sulfide |
ND |
0.03mg/Nm³ |
On target |
Atmospheric |
|||
Chlorobenzene |
ND |
0.4mg/Nm³ |
On target |
Atmospheric |
|||
Aniline |
ND |
0.4mg/Nm³ |
On target |
Atmospheric |
|||
Particulate matter |
0.318mg/Nm³ |
1.0mg/Nm³ |
On target |
Atmospheric |
|||
Hydrogen bromide |
ND |
0.2mg/Nm³ |
On target |
Atmospheric |
|||
Odor concentration |
<10 (dimensionless) |
20 (dimensionless) |
On target |
Atmospheric |
|||
Sewage treatment station discharge outlet |
pH |
7.53~7.61 |
6.5~9.5 |
On target |
Qingyuan Water |
||
suspended objects |
14mg/L |
400mg/L |
On target |
Qingyuan Water |
|||
COD |
38mg/L |
500mg/L |
On target |
Qingyuan Water |
|||
5-day BOD |
9.6mg/L |
350mg/L |
On target |
Qingyuan Water |
|||
Ammonia |
0.624mg/L |
45mg/L |
On target |
Qingyuan Water |
|||
Total nitrogen |
1.23mg/L |
70mg/L |
On target |
Qingyuan Water |
|||
Fluoride |
0.668mg/L |
20mg/L |
On target |
Qingyuan Water |
|||
TP |
0.15mg/L |
8mg/L |
On target |
Qingyuan Water |
|||
Sulfide |
ND |
1.0mg/L |
On target |
Qingyuan Water |
|||
Petroleum |
0.69mg/L |
15mg/L |
On target |
Qingyuan Water |
|||
Volatile phenols |
ND |
1mg/L |
On target |
Qingyuan Water |
|||
Organohalogen adsorption* |
94ug/L |
8mg/L |
On target |
Qingyuan Water |
Related News
No. 1717, Donghai Road, Yangkou Chemical Industry Park, Sahouguang City, Shandong Province
Tel. of Marketing Department: 0086-536-5454568
Office Tel.: 0086-536-5456000
© COPYRIGHT 2023 Shandong Futong Chemical Co., Ltd. | SEO Powered by: 300.cn weifang Business license